Esserbus ® Alarm Transponder (Part No. 808623) - Honeywell ESSER FACP Technical Information

Table of Contents

Advertisement

12.1 esserbus
®
As a loop device on the loop, the esserbus
detectors, manual call points (MCP) without addressing, and third-party detectors. In addition, two
programmable relay outputs are also available.
Monitoring via the EOL terminating devices (Part No. 808624 / 808626) is required for the connection of fire
detectors and for the controlling of alarm signaling devices. The enclosed resistors can be used to connect the
floating contacts.
The planning of the alarm devices that can be connected is carried out via a calculation tool, which is part of the
tools 8000 service and programming software.
The esserbus
®
alarm transponder requires an external voltage supply. These can be programmed in monitored
mode. An optional Voltage Converter (Part No. 781336) is also required for 12 V DC operation.
According to DIN VDE 0833-2, fire detectors from max. one detection area and alarm devices and tools from
one alarm area must be connected to one alarm transponder.
Fig. 47: esserbus
®
alarm transponder
Specifications
Loop
Rated voltage
Rated current
External power supply
Operating voltage
Current consumption
Quiescent current
Inputs
Current consumption
Length of connection cable
Monitoring
Relays
Contact rating
Monitoring relay
Connection terminals
Ambient temperature
Storage temperature
Rel. humidity
Protection rating
Weight
Dimensions (w x h x d)
Specification
VdS approval
Declaration of Performance
For further information and accessories refer to product catalogue and documentation of the devices.
TI 798960.GB0 / 04.20
alarm transponder (Part No. 808623)
®
transponder enables the connection of automatic standard fire
Features
4 detector zone inputs
Conventional connection of standard fire detectors and signaling
devices
Loop monitoring in compliance with EN 54-13
Integrated loop isolator
2 programmable relay outputs
Programmable reset relay function
: 8 V DC ... 42 V DC
: approx. 90 µA @ 19 V DC
: 10 V DC ... 28 V DC
: max. 120 mA @ 12 V DC
: approx. 12 mA @ 12 V DC
: max. 25 mA @ 9 V DC
: max. 1.000 m
: EOL-I or 10 kΩ / ±40%
: max. 30 V DC / 1 A
: EOL-O or 10 kΩ / ±40%
: max. 1,5 mm² (AWG 30-14)
: -10 °C ... +50 °C
: -25 °C ... +75 °C
: ≤ 95% (no condensation)
: IP 40 (with housing)
: approx. 28 g
: 82 x 72 x 20 (mm)
: EN 54-17 : 2005
: G 210020
: DoP-21057130701