Chapter 4
Error Messages
Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
EID-5172
Provisionable patchcords can not be created between
incompatible ports.
EID-5173
Some Server Trail terminations were not repaired.
WID-5174
Routing constraints has been specified only for protected path.
Can be evaluated to move some constraints on working path
since these are treated with priority.
Please consider that some good constraint on protected part
may not be evaluated correctly since that constraint may be
already applied to working path by auto-routing.
Do you want to continue anyway?
EID-5175
Unknown Error occurred while updating the SRLG value on the
CRS node(s).
{0}
WID-5176
One or more SVLANs are invalid.
Please remove them before continuing.
EID-6000
This platform does not support power monitoring thresholds.
EID-6001
One of the XC cards has failures or is missing.
EID-6002
One of the XC cards is locked.
EID-6003
The OSC termination could not be created.
This ring ID is already assigned.
EID-6004
A system reset cannot be performed while a BLSR/MS-SPRing
is provisioned on the node.
EID-6005
The timing references could not be assigned.
- Only two E1 or BITS interfaces can be specified.
- E1 interfaces cannot be retimed and used as a reference.
- BITS-2 is not supported on this platform.
EID-6006
The timing references could not be assigned.
- An NE reference can only be used if the timing mode is LINE.
- A BITS reference can only be used if the timing mode is not
LINE.
- A Line reference can only be used if the timing mode is not
EXTERNAL.
EID-6008
SF BER and SD BER are not provisionable on the protect line
of a protection group.
WID-6009
If autoadjust GFP buffers is disabled, GFP buffers available
must be set to an appropriate value based on the distance
between the circuit endpoints.
WID-6010
If auto detection of credits is disabled, credits available must be
set to a value less than or equal to the number of receive credits
on the connected FC endpoint.
78-19418-01
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
Description
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Check whether all the cross-connect cards
are installed and working.
Unlock the cross-connect card.
Enter a new ID for the ring.
Remove the BLSR or MS-SPRing from the
node and continue with the reset procedure.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the warning message text.
Refer to the warning message text.
4-45