Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
EID-3244
An {0} exists on the selected ports.
Therefore, you must create the {1}s one by one.
WID-3245
The port you have chosen as an {1} endpoint already supports
an {0}. The port cannot support both DCCs. After the {1} is
created, verify that no EOC alarms are present and then delete
the {0} to complete the upgrade.
EID-3246
The wizard was not able to validate the data.
{0}
EID-3247
An ordering error occurred. The absolute value should be {0}. The absolute value entered was wrong.
EID-3248
The value for the parameter {0} is invalid.
EID-3249
The voltage increment value is invalid.
EID-3250
The power monitor range is invalid.
EID-3251
The requested action could not be completed.
{0}
EID-3252
No download has been initiated from this CTC session.
EID-3253
The reboot operation failed. {0}
EID-3254
An error occurred during validation. {0}
EID-3255
You cannot change the timing configuration because a
Manual/Force operation is in effect.
WID-3256
The timing reference(s) could not be assigned because one or
more of the timing reference(s):
- is already used and/or
- has been selected twice and/or
- is attempting to use the same slot twice.
Please verify the settings.
EID-3257
Duplicate DCC numbers are not permitted. {0}.
EID-3258
A software error occurred while attempting to download the
file.
Please try again later.
EID-3259
An error occurred while creating the FC-MR threshold.
EID-3260
An error occurred while provisioning the internal subnet:
{0}
EID-3261
The port rate provisioning cannot be changed while circuits
exist on this port.
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
4-26
Chapter 4
Description
The specified DCC already exists on the
selected port. You can create a DCC of
another type.
The port selected as a DCC endpoint
already supports another DCC. Refer to the
warning message text.
CTC encountered an error.
CTC changed the incorrect parameter.
Refer to the error message text.
Refer to the error message text.
CTC could not complete the specified
action.
Refer to the error message text.
Refer to the error message text.
The Cisco Transport Controller (CTC) was
unable to validate the values entered by the
user, specified by {0}. This error message is
common to several different provisioning
tabs within the CTC.
Refer to the error message text.
Refer to the warning message text.
CTC detected more than one occurrence of
the a DCC number. Remove one of them.
Refer to the error message text.
You must create a Fibre Channel Multirate
(FC_MR) card threshold.
The specified internal subnet could not be
provisioned.
Refer to the error message text.