Download Print this page

Cisco ONS 15454 Troubleshooting Manual page 35

Hide thumbs Also See for ONS 15454:

Advertisement

Chapter 4
Error Messages
Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
EID-4034
WDMANS parameter already present.
EID-4035
WDMANS parameter is not valid.
EID-4036
WDMANS parameter cannot be removed.
This may be in use by the system.
EID-4037
This operation is not supported on the protect entity of a
protection group.
EID-5000
A valid route cannot be found for the tunnel change request.
EID-5001
The tunnel could not be changed.
EID-5002
The tunnel could not be restored and must be recreated
manually.
EID-5003
The circuit roll failed.
{0}
EID-5004
There is already one four-fiber {0} provisioned on the set of
nodes involved in {1}. The maximum number of four-fiber {0}
rings has been reached for that node.
WID-5005
A non-zero hold-off time can violate switching time standards,
and should only be used for a circuit with multiple path
selectors.
WID-5006
Warning: A different secondary {0} node should only be used
for DRI or open-ended path protected circuits.
WID-5007
If you change the scope of this view, the contents of this profile
editor will be lost.
WID-5008
Please ensure that all the protection groups are in proper states
after the cancellation.
WID-5009
The circuit {0} is not upgradable.
No {1} capable {2}s are available at the node {3}.
EID-5010
The domain name already exists.
EID-5011
The domain name cannot exceed {0} characters.
WID-5012
The software load on {0} does not support the addition of a
node to a 1+1 protection group.
EID-5013
{0} does not support the bridge and roll feature. Please select a
different port.
EID-5014
An automatic network layout is already in progress.
Please wait for it to complete before running it again.
WID-5015
{0} cannot be applied to {1}.
78-19418-01
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
Description
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
There is already one 4F MS-SPRing
provisioned on the set of nodes involved in
the ring. The maximum number of 4F
MS-SPRing rings has been reached for that
node.
Refer to the warning message text.
You should use different secondary end
point only for DRI or open-ended path
protected circuits.
Refer to the warning message text.
Refer to the warning message text.
No VT/VC capable STSs/VCs are available
at the node.
Refer to the error message text.
You may have reached the maximum
number of characters.
Refer to the warning message text.
The specified port does not support Bridge
and Roll.
You must for the automatic network layout
to complete before running it again.
You cannot apply the admin state operation,
specified by {0}, to port count, specified by
{1}.
4-35

Advertisement

loading