Chapter 4
Error Messages
Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
EID-3307
An error occurred while creating a connection object at {0}.
EID-3308
DWDM links can be used only for optical channel circuits.
EID-3309
The link was excluded because it was in the wrong direction.
EID-3310
The DWDM link does not have wavelengths available.
EID-3311
The laser is already on.
EID-3312
The power setpoint cannot be changed.
{0} {1}
EID-3313
The offset cannot be modified because the service state of the
port is IS.
EID-3314
The requested action is not allowed.
The state value is invalid.
EID-3315
This operation cannot be performed.
EID-3316
The node side is invalid.
EID-3317
The ring name is too long.
EID-3318
The ring name is invalid.
EID-3319
The wrong line was selected.
EID-3320
The optical link could not be deleted.
EID-3321
This feature is unsupported by this version of software.
EID-3322
The equipment is not plugged in.
EID-3323
The APC system is busy.
EID-3324
There is no path to regulate.
EID-3325
The requested action is not allowed.
EID-3326
The input was invalid.
EID-3327
An error occurred while retrieving thresholds.
EID-3328
An error occurred while applying changes to row {0}.
The value is out of range.
EID-3330
Unable to switch to the byte because an overhead channel is
present on this byte of the port.
EID-3331
An error occurred while applying changes to the row.
78-19418-01
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
Description
CTC encountered an error at the specified
connection while creating the connection.
Refer to the error message text.
The optical channel (circuit) does not allow
the specified link to be included because it
is in the wrong optical direction.
Refer to the error message text.
Refer to the error message text.
CTC cannot change the power setpoint. The
new setpoint would either make the
thresholds inconsistent or set the fail
threshold outside the range.
Refer to the error message text.
Refer to the error message text.
CTC is unable to perform operation.
This task was applied to the wrong node
side.
Reduce the number of characters in the
name.
The name you entered is illegal.
Select another line
CTC cannot delete the optical link.
Refer to the error message text.
Plug-in the equipment and proceed.
Automatic Power Control (APC) system is
busy.
There is no circuit path to regulate.
Generic DWDM provisioning failure
message.
The input value is incorrect.
There was an error retrieving the thresholds.
This message is displayed only for the
OSCM/OSC-CSM line thresholds.
There was an error applying the changes to
the specified row. The value is out of range.
Refer to the error message text.
Refer to the error message text.
4-29

Advertisement