Download Print this page

Cisco ONS 15454 Troubleshooting Manual page 16

Hide thumbs Also See for ONS 15454:

Advertisement

Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
WID-2326
Currently, CTC does not support bridge and roll on circuits that
are entirely created by TL1. To continue with bridge and roll in
CTC, the selected circuits must be upgraded.
Is it OK to upgrade the selected circuits and continue the bridge
and roll operation?
WID-2327
Currently, CTC does not support bridge and roll on circuits that
are partially created by TL1. To continue with bridge and roll
in CTC, the selected circuits must be upgraded.
Is it OK to upgrade the selected circuits and continue the bridge
and roll operation?
EID-2328
An error occurred during the circuit reconfiguration.
{0}
EID-2329
{0} of {1} circuits could not be successfully created.
EID-2330
An error occurred during circuit verification. The selected {0}
is invalid!
{1}
EID-2331
Deleting {0} might be service affecting.
EID-2332
A validation error occurred in row {0}.
{1} hold-off timer for {2} must be between {3}-10,000 ms, in
steps of 100 ms.
EID-2333
The SSLIOP port cannot have the same port value as IIOP port.
Please change it and apply again.
EID-3001
An Ethernet RMON threshold with the same parameters
already exists. Please change one or more of the parameters and
try again.
EID-3002
An error occurred while retrieving defaults from the node: {0} There was an error while retrieving the
EID-3003
The file {0} cannot be loaded.
EID-3004
Properties cannot be loaded from the node.
EID-3005
NE update properties cannot be saved to the file {0}.
EID-3006
NE update properties cannot be loaded from the node.
EID-3007
An error occurred while provisioning the {0}.
EID-3008
This is not a valid card.
EID-3009
No {0} was selected.
EID-3010
A bidirectional optical link could not be created.
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
4-16
Chapter 4
Description
Refer to the warning message text.
Refer to the warning message text.
The attempt to reconfigure the specified
circuit has failed.
A few circuits could not be created.
The selected item, specified by {0}, is
invalid as per the details, specified in {1}.
Deleting the item can affect the service of
CTC.
Refer to the error message text.
Refer to the error message text.
Change a few parameters in an Ethernet
remote monitoring (RMON) threshold and
try again.
defaults from the specified node.
CTC cannot load the specified file.
Refer to the error message text.
CTC cannot save the network element (NE)
update values to the specified file.
Refer to the error message text.
There was a provisioning error for the
specified item.
You cannot perform DWDM automatic
node setup (ANS) from the Card view.
Please navigate to the Node view and try
again.
Select the specified item, for example,
VLAN, port, slot, etc.
Refer to the error message text.