Table 4-1
Error Messages (continued)
Error/Warning
ID
Error/Warning Message
EID-2121
The ring cannot be upgraded.
{0}
EID-2122
The ring speed for is inadequate for the upgrade procedure.
Only {0} (or higher) {1} can be upgraded to four-fiber.
EID-2123
Verify that the following nodes have at least two in-service
ports with the same speed as the two-fiber {0}. The ports cannot
serve as timing references, and they cannot have DCC
terminations or overhead circuits.
{1}
EID-2124
You cannot add this span because it is connected to a node that
already has the east and west ports defined.
EID-2125
You cannot add this span as it would cause a single card to host
both the east span and the west span. A card cannot protect
itself.
EID-2126
An error occurred while provisioning the OSPF area.
{0}
EID-2127
You cannot add this span. It would cause the following
circuit(s) to occupy different {0} regions on different spans:
{1}
Either select a different span or delete the above circuit(s).
EID-2128
The state is invalid.
EID-2129
You cannot use same slot for east and west protect ports.
EID-2130
The ring ID value, {0}, is not valid. Please enter a valid number
between 0 and 9999.
EID-2131
The reversion cannot be set to INCONSISTENT.
EID-2135
The overhead circuit preferences could not be stored:
{0}
EID-2137
An error occurred during the circuit merge.
{0}
EID-2138
Not all destinations could be deleted.
Please try again.
EID-2139
An error occurred while updating the destinations.
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.2
4-10
Chapter 4
Description
CTC cannot upgrade the specified ring.
You have selected an incorrect ring speed
for upgrade. Only rings within the specified
parameters can be upgraded to 4-fiber
MS-SPRing.
Nonupgradable nodes. Verify that the
specified nodes have at least two
unlocked-enabled ports with the same speed
as the 2-fiber MS-SPRing.
The specified ports cannot serve as a timing
reference, and they cannot have data
communications channel (DCC)
terminations or overhead circuits.
Refer to the error message text.
Refer to the error message text.
There is an Open Shortest Path First (OSPF)
area error.
A circuit cannot occupy different STS/VC
regions on different spans. You may add a
different span or delete the specified circuit.
An internal error occurred while trying to
remove a span from a MS-SPRing.
This alarm occurs in the network-level
MS-SPRing creation dialog box.
Refer to the error message text.
Enter a ring ID value between 0 and 9999.
You must select another reversion type.
Input/Output error. Unable to store
overhead circuit preferences.
There was an error while merging the
circuits.
Refer to the error message text.
There was an error in updating the circuit
destinations.
Error Messages