Replace Front Panel

The front panel of the Thor VM2 is field replaceable. The front panel assembly contains the integrated keypad and touch screen.
Should either of these components fail, the front panel assembly can easily be replaced to reduce downtime.

Equipment Required

The following equipment is user-supplied:
• Torquing tool capable of measuring inch pounds
• #2 Phillips screwdriver bit

Replacement Procedure

CAUTION - Before replacing the Thor VM2 front panel,
1. Place the Thor VM2 on a clean, well-lit surface before perform-
ing the front panel replacement.
2. Shutdown the Thor VM2.
3. Remove the Thor VM2 from the dock.
4.
Disconnect UPS Battery
5. Loosen the twelve (12) captive M3 screws holding the front
panel. Use a #2 Phillips bit.
6.
7. Carefully lift the front panel away from the device.
Wiring Connector
on Thor VM2
8. Position the replacement front panel so wiring connector on the back of the front panel lines up with the connector on
the Thor VM2.
9. Gently press the front panel into place.
10. Tighten the twelve (12) captive M3 screws. In the order shown in the top figure above, use a #2 Phillips bit and torque
the screws to 6-7 inch pounds.
11. Reinstall the Thor VM2 in the dock.
4 - 52
(page 4-49).
Disconnect UPS Battery
(page 4-49).
1
9
12
3
8
5
6
7
Wiring Connector
on Front Panel
4
11
10
2