Manual Control Wiring Diagram
Ignition wire must be left unconnected and AC/DC power mode must be from the Power Schemes tab of the
Power Options
(page 5-20) control panel.
Existing Circuitry On Vehicle
Battery
Main Switch
+Vo
-Vo
Fuse - See
Warning
statement below
See Caution statement below
CAUTION
For battery powered vehicles:
• Red wire is connected to battery positive. If there is a red wire and a red/white wire, twist them
together and connect to battery positive.
• Black wire must be connected to battery negative. If there is a black wire and a black/white wire, twist
them together and connect to battery negative.
• Green wire must be connected to the vehicle chassis ground.
For internal combustion engine powered vehicles:
• Red wire is connected to battery positive. If there is a red wire and a red/white wire, twist them
together and connect to battery positive.
• Black wire must be connected to battery negative. If there is a black wire and a black/white wire, twist
them together and connect to battery negative.
• Green wire is connected to the vehicle chassis ground, which can also be battery negative.
WARNING
For proper and safe installation, the input power cable must be connected to a fused circuit on the ve-
hicle. If the supply connection is made directly to the battery, the fuse should be installed in the positive
lead within 5 inches of the battery's positive (+) terminal. Use VM3055FUSE (or equivalent) to install the
fuse as shown below:
• For 12VDC input, use the 10A fuse from the kit or a slow blow fuse that has a DC voltage rating
greater than 12VDC.
• For 24VDC input, use the 6A fuse from the kit or a slow blow fuse that has a DC voltage rating greater
than 24VDC.
• For 36VDC input, use the 4A fuse from the kit or a slow blow fuse that has a DC voltage rating greater
than 36VDC.
• For 48VDC input, use the 3A fuse from the kit or a slow blow fuse that has a DC voltage rating greater
than 48VDC.
Note: For North America, a UL Listed fuse is to be used.
Cable for optional
screen blanking
connection
Red/White (if present)
Red
Black/White (if present)
Black
Green
Blue
(not connected)
Quick Mount
Smart Dock
COM1 or COM2
Connector
Circular
Power
Connector
4 - 23