NEC NovaScale R480 E1 User Manual page 269

Table of Contents

Advertisement

Jumper switch location for
clearing the BMC configuration
data
3.
Connect the power cord.
4.
Wait at least 30 seconds (without powering on the server), and unplug the power cord.
5.
Restore the BMC configuration jumper switch settings and power on the server for reconfiguration.
Event logs when using the Intel Network adapter teaming
Event Type:
Warning
Event Source:
IANSMiniport
Event Category:
None
Event ID:
11
Description:
Adapter link down: Intel(R)PRO/1000 ----
Event Type:
Warning
Event Source:
IANSMiniport
Event Category:
None
Event ID:
13
Description:
Intel(R)PRO/1000 ---- has been deactivated from the team.
Event Type:
Error
Event Source:
IANSMiniport
Event Category:
None
Event ID:
16
Description:
Team #0: The last adapter has lost link.
Team network connection has been lost.
Event Type:
Warning
Event Source:
IANSMiniport
Event Category:
None
Event ID:
22
Description:
Primary Adapter does not sense any Probes:
Intel(R)PRO/1000 ---- Possible reason: partitioned Team.
The above-mentioned event log will appear when the system starts. There is no problem in LAN driver operation.