Messages displayed on the lower line (BMC Message)
When the STATUS lamp is off
Description
On-screen
message
Recommended action
SMI Timeout
A timeout error occurred during the system management interrupt.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
If the error persists, contact your service representative.
DUMP Request!
The DUMP switch was pressed.
Wait until the OS dump process completes.
If the dump process is not completed, take one of the following steps.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
If the error persists, contact your service representative.
Proc1 Thermal Trip
A forced power-off occurred due to a thermal error in processor #1.
Proc2 Thermal Trip
A forced power-off occurred due to a thermal error in processor #2.
Proc3 Thermal Trip
A forced power-off occurred due to a thermal error in processor #3.
Proc4 Thermal Trip
A forced power-off occurred due to a thermal error in processor #4.
1. Reboot (reset) the server.
2. Check if the fans in the server work normally.
3. Check the installation status of failed processor.
4. Replace the failed processor.
If the error persists, contact your service representative.
Proc1 IERR
An internal error (IERR) was detected in processor #1.
Proc2 IERR
An internal error (IERR) was detected in processor #2.
Proc3 IERR
An internal error (IERR) was detected in processor #3.
Proc4 IERR
An internal error (IERR) was detected in processor #4.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
3. Check installation status of the failed processor.
4. Replace the failed processor.
If the error persists, contact your service representative.
Proc1 Config Err
The processor installed in the processor #1 slot is unsupported, has failed,
or its combination is illegal.
Proc2 Config Err
The processor installed in the processor #2 slot is unsupported, has failed,
or its combination is illegal.
Proc3 Config Err
The processor installed in the processor #3 slot is unsupported, has failed,
or its combination is illegal.
Proc4 Config Err
The processor installed in the processor #4 slot is unsupported, has failed,
or its combination is illegal.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
3. Check the installation status of the failed processor.
4. Replace the failed processor.
If the error persists, contact your service representative.
Proc1 Didn't Start
Failed to start processor #1.
Proc2 Didn't Start
Failed to start processor #2.
Proc3 Didn't Start
Failed to start processor #3.
Proc4 Didn't Start
Failed to start processor #4.
Connect the AC power cord again, and reboot the server.
Connect the AC power cord again, and reboot the server.
Connect the AC power cord again, and reboot the server.
Connect the AC power cord again, and reboot the server.