Option
Parameter
HTTPS
[Disabled]
Enabled
HTTPS Port
[443]
Number
Telnet
[Disabled]
Enabled
Telnet Port
[23]
Number
SSH
[Disabled]
Enabled
SSH Port Number
[22]
Clear BMC
[Enter]
Configuration
IMPORTANT:
Executing the "Load Setup Defaults" in the BIOS SETUP utility does not restore the
default value for the settings related to the management LAN of the BMC. To restore
the default value, you need to execute a Clear BMC Configuration.
It takes a short while until the initialization completes after the execution of the Clear
BMC Configuration.
Executing the Clear BMC Configuration also clears settings made in NEC DianaScope.
Before the execution, be sure to make the backup copy of the settings information of
NEC DianaScope.
NOTE:
Executing [Save Custom Defaults/Load Custom Defaults] of BIOS SETUP does
not save the settings you have made in the BMC LAN Configuration menu.
Description
Set it to [Enabled] to use the HTTPS
communication for the Web interface.
Specifies the TCP port number which
the management LAN uses for the
HTTPS communication.
Set it to [Enabled] to use the Telnet
communication as a command line
interface.
Specifies the TCP port number to be
used for the Telnet communication.
Set it to [Enabled] to use the SSH
communication as a command line
interface.
Specifies the TCP port number to be
used for SSH communication.
Press Enter and select "Yes" to
initialize the BMC configuration.
Notes on performing Clear BMC Configuration
4-30
Your Setting
[
]: Factory-set