Manual Rebuild
The procedures described below are based on the following assumption:
One of the HDDs failed in a RAID5 virtual disk configured with three HDDs.
Power off the server and replace the failed HDD with a new one. The Auto Rebuild feature is disabled for non-hot-swap
replacement. Use the Manual Rebuild feature to recover the virtual disk as described below.
1.
Start WebBIOS.
Make sure that the status for the replaced HDD is indicated as "UNCONF GOOD" in the right frame of the
Top Menu.
In the example below, the hard disk drive in slot number 2 has been replaced.
The indication "PD Missing from DGx: Slot 2: xxxxx MB" indicates that the PD (physical drive)installed in
slot number 2 was removed.
2.
Select "2:0:2" (newly connected HDD) in [Physical Drives].
3.
The properties for the Physical Drive are displayed.
4.
Select "Make Global HSP" or "Make Dedicated HSP", and then click [Go].
5.
When the [Rebuild Progress] is displayed, click [Home] to go back to the WebBIOS Top Menu.
4-77