Error
Error message
code
reading.
0B71
System Temperature out of the range.
0B74
The error occurred during voltage sensor
reading.
0B75
System voltage out of the range.
0B78
The error occurred during fan sensor reading
0B7C
The error occurred during redundant power
module confirmation
0B7D
The normal operation can't be guaranteed
with use of only one PSU
0B7E
Mismatch AC Voltage detected.
0B7F
Insufficient Power Supply Unit Configuration
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core hardware failure.
0B83
BMC IBF or OBF check failed.
0B8A
BMC SEL area full.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
0B92
Internal Use Area of BMC FRU corrupted.
0B93
BMC SDR Repository empty.
0B94
IPMB signal lines do not respond.
0B95
BMC FRU device failure.
0B96
BMC SDR Repository failure.
Recommended Action
A fan failure or fan clogging may be occuring. Contact
your service representative to request the
maintenance.
Contact your service representative.
Contact you service representative to replace the
power supply unit.
Contact you service representative to add an additional
power supply unit or replace the existing power supply
unit.
Check if the same voltage (100 or 200 VAC) is input to
both power supply units.
Check the installation status of the power supply units.
If the error cannot be corrected, contact your service
representative.
Check the installation status of power supply units.
If the error cannot be corrected, contact your service
representative.
Turn off the power once and then on again to start the
server.
If the error cannot be corrected, contact your service
representative.
All the commands and functions other than the FRU
command and the EMP function can be used. This is
not a fatal error.
Turn off the power once and then on again to restart
the server.
If the error cannot be corrected, contact your service
representative.
Turn off the power once and then on again to restart
the server.
If the error cannot be corrected, contact your service
representative.
All the functions other than the function of accessing to
SMC through IPMB can be used. This is not a fatal
error.
Turn off the power once and then on again to restart
the server.
If the error cannot be corrected, contact your service
representative.
All the commands and functions other than the FRU
command and the EMP function can be used. This is
not a fatal error.
Turn off the power once and then on again to restart
the server.
If the error cannot be corrected, contact your service
representative.
Turn off the power once and then on again to start the
8-16