Description
On-screen message
Recommended action
IO +1.0V Alm 07
+1.0V voltage warning (upper limit) occurred in the I/O riser board.
IO +1.0V Alm 00
+1.0V voltage warning (lower limit) occurred in the I/O riser board.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power
3. Check the installation status of the I/O riser board.
If the error persists, contact your service representative.
Battery Alm 07
Voltage warning (upper limit) occurred on lithium battery.
Battery Alm 00
Voltage warning (lower limit) occurred on lithium battery.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power
3. Check the installation status of the lithium battery on the base board.
If the error persists, contact your service representative.
FP Temp Alm 07
A high temperature warning occurred in the front panel.
FP Temp Alm 00
A low temperature warning occurred in the front panel.
BB Temp Alm 07
A high temperature warning occurred in the base board.
BB Temp Alm 00
A low temperature warning occurred in the base board.
Check if the fans in the server are working normally.
If the error persists, contact your service representative.
SASBP Temp NCAlm
A temperature warning occurred in the SAS riser board.
Mem A Temp Alm 07
A high temperature warning occurred in the memory board A.
Mem A Temp Alm 00
A low temperature warning occurred in the memory board A.
Mem B Temp Alm 07
A high temperature warning occurred in the memory board B.
Mem B Temp Alm 00
A low temperature warning occurred in the memory board B.
Mem C Temp Alm 07
A high temperature warning occurred in the memory board C.
Mem C Temp Alm 00
A low temperature warning occurred in the memory board C.
Mem D Temp Alm 07
A high temperature warning occurred in the memory board D.
Mem D Temp Alm 00
A low temperature warning occurred in the memory board D.
1. Check if the fans in the server work normally.
2. Check installation status of the failed memory board.
If the error persists, contact your service representative.
PS1 Temp Alm 07
A high temperature warning occurred in the power supply unit #1.
PS1 Temp Alm 00
A low temperature warning occurred in the power supply unit #1.
PS2 Temp Alm 07
A high temperature warning occurred in the power supply unit #2.
PS2 Temp Alm 00
A low temperature warning occurred in the power supply unit #2.
1. Check if the fans in the power supply unit work normally.
2. Check if the fans in the server work normally.
3. Check the installation status of the failed power supply unit.
If the error persists, contact your service representative.
Proc1 Therm % 07
A high temperature warning occurred in processor #1.
Proc1 Therm % 00
A low temperature warning occurred in processor #1.
Proc2 Therm % 07
A high temperature warning occurred in processor #2.
Proc2 Therm % 00
A low temperature warning occurred in processor #2.
Proc3 Therm % 07
A high temperature warning occurred in processor #3.
Proc3 Therm % 00
A low temperature warning occurred in processor #3.
Proc4 Therm % 07
A high temperature warning occurred in processor #4.
Proc4 Therm % 00
A low temperature warning occurred in processor #4.
1. Check if the fans in the server work normally.
2. Check the installation status of the failed processor and heat sink.
If the error persists, contact your service representative.
Power Unit Alm 1
An error occurred in the power supply unit #1.
Power Unit Alm 2
An error occurred in the power supply unit #2.
1. Check the connection status of the AC power cord of the failed power
2. Turn off the DC power of the server, and disconnect the AC power
If the error persists, contact your service representative.
cord. Connect the AC power cord again, and reboot the server.
cord. Connect the AC power cord again, and reboot the server.
supply unit.
cord. Connect the AC power cord again, and reboot the server.
8-38