D-Link DGE-560SX User Manual page 135

Gigabit fiber (lc) pci express server adapter
Hide thumbs Also See for DGE-560SX:
Table of Contents

Advertisement

C5
VPD
C6
ASF Hardware
C7
Expansion
ROM
C8
CPU Fetch
Group D: Driver Associated Tests
0x08
0xFFFF
0x09
0x0000
0x0A
0x7C00
0x10
0x0000
0x11
0x7C00
0x19
0x7C00
0x1E
0x0000
0x1F
0x0000
The VPD test first saves the contents of the vital product data
(VPD) memory before performing the test. The test then writes 1
of the 5 test data patterns (0xFF, 0xAA, 0x55, increment data, or
decrement data) into VPD memory. By default, an incremental
data pattern is used. The test writes and reads back the data for
the entire test range, and then restores the original contents of
the VPD memory.
Reset Test. This test sets the reset bit and polls for self-clearing
bits. This test verifies the reset value of the registers.
Event Mapping Test. This test sets the SMB_ATTN bit. By
changing ASF_ATTN_ LOC bits, the test verifies the mapping bits
in TX_CPU or RX_CPU event bits.
Counter Test
Clears WG_TO, HB_TO, PA_TO, PL_TO, RT_TO bits (by
setting the bits) and ensures that the bits clear.
Clears the timestamp counter. Writes a 1 to each of the
PL, PA, HB, WG, RT counters. Sets the TSC_EN bit.
Polls each PA_TO bit and counts up to 50. Checks if the
PL_TO bit is set at the end of the count to 50. Continues
to count up to 200. Checks if all other TO bits are set and
verifies if the timestamp counter is incremented.
This test tests the ability to enable, disable, and access the
expansion read-only memory (ROM) on the adapter.
This test tests the PCU instruction fetch logic 100 times.
135
D-Link DGE-560SX User Guide