Modem Configuration and Profile
Example
AT&F?
&F: 0
OK
Z, Reset to Default Configuration
This command drops the current call, and resets the values to default configuration.
Command Type
Set
Read
Test
The following table shows the Z parameters.
<Parameter>
<value>
Example
ATZ0
OK
Sleep Mode Commands
When the G24 is connected using RS232 connection to external device, a sleep mechanism is
available. In order to improve the power consumption, the G24 supports a low-power
consumption mode, called "Sleep mode". The G24 has internal decision conditions for entering
and exiting sleep mode. As the terminal and the G24 operate in a combined system, and as the
communication between the G24 and the terminal must be reliable, there should be a mechanism
agreed upon by both the G24 and the terminal to co-ordinate their separate sleep mode entering
and exiting sequences. The G24 will not enter sleep mode unless the terminal enables the G24
3-282
Syntax
Response/Action
ATZ<value>
OK
or:
+CMS ERROR: <err>
Table 3-188: Z Parameters
0
Set to user profile 0
1
Set to user profile 1
The default value is 0.
AT Commands Reference Manual
Remarks
The Read command for Z is not
defined, and therefore is not supported
by the G24. The G24 returns an error.
The Test command for Z is not
defined, and therefore is not
supported by the G24. The G24
returns an error
.
Description
December 31, 2007