Sony ZRD-1 Installation Manual page 65

Hide thumbs Also See for ZRD-1:
Table of Contents

Advertisement

(4) Align the display unit in the Z direction.
Measuring device: Monitor of unit alignment tool
Adjustment device: Eccentric pin (short) and hexagon wrench
Specification:
t
. "2-4-7. Adjustment Screen of Unit Alignment Tool"
. "2-4-8. Adjustment Mechanism"
For the alignment in the Z direction
around this area, rotate the eccentric
pin and hexagon wrench in the lower
right portion.
For the alignment in the Z direction around
this area, rotate the eccentric pin and
hexagon wrench in the lower left portion.
(5) Insert the hexagon wrench into the four shafts, then tighten it in the clockwise direction. The
shafts are locked.
(6) Remove all eccentric pins (short) and hexagon wrenches.
(7) Check that the specification is met. If the specification is not met, align the display unit in the Z
direction again.
(Refer to steps (1) to (6).)
Measuring device: Monitor of unit alignment tool
Specification:
ZRD-1/ZRD-2/ZRCT-100/ZRCT-200
0 ?20 μm
For the alignment in the Z direction around this area, rotate the eccentric
pin and hexagon wrench in the upper portion of the side.
For the alignment in the Z direction around this area, rotate the eccentric
pin and hexagon wrench in the lower portion of the side.
0 ?40 μm
Eccentric pin (short)
Hexagon wrench
Eccentric pin (short)
Hexagon wrench
2-31 (E)