(5) Switch the monitor screen to the X/Y direction adjusting screen. ([X, Y] button)
(6) Align the display unit in the X direction.
Measuring device:
Adjustment device:
Specification (LED linearity in the X direction): 0 ?80 μm
t
. "2-4-7. Adjustment Screen of Unit Alignment Tool"
. "2-4-8. Adjustment Mechanism"
(7) Insert the hexagon wrench into the two shafts, then tighten them by rotating it in the clockwise
direction (2).
The shafts are locked.
(8) Remove all eccentric pins (short) and hexagon wrenches.
(9) Check that the specifications are met. If the specification is not met, align the display unit in the
Z direction or the X direction again. (Refer to steps (1) to (8).)
Measuring device: Monitor of unit alignment tool
Z specification: 0 ?40 μm
X specification: 0 ?80 μm
ZRD-1/ZRD-2/ZRCT-100/ZRCT-200
X direction
Monitor of unit alignment tool
Eccentric pins (short) inserted into the X adjust-
ing hole and hexagon wrench
X adjusting hole
2-23 (E)