[Parameter]
time
[Initial value]
terminal-watch interval 1800
[Input mode]
L2MS mode
[Description]
Specifies the time interval at which network device information is acquired. Information for the devices existing on the network
is acquired when the time specified by time has elapsed.
If this command is executed with the "no" syntax, the setting returns to the default.
[Note]
If the terminal management function is not enabled, terminal information is not acquired, regardless of the setting of this
command.
[Example]
Set the watch interval to 3,600 seconds.
SWR2311P(config)#l2ms configuration
SWR2311P(config-l2ms)#l2ms enable
SWR2311P(config-l2ms)#l2ms role master
SWR2311P(config-l2ms)#terminal-watch enable
SWR2311P(config-l2ms)#terminal-watch interval 3600

4.20.8 Set L2MS control frame transmit/receive

[Syntax]
l2ms filter enable
l2ms filter disable
no l2ms filter
[Keyword]
enable
disable
[Initial value]
l2ms filter disable
[Input mode]
interface mode
[Description]
Prevents L2MS control frames from being transmitted or received.
If this command is executed with the "no" syntax, L2MS control frames can be transmitted and received.
[Note]
This command cannot be specified for the following interfaces.
VLAN interface
A physical interface inside a logical interface
A physical interface inside a logical interface operates according to the setting of this command on the interface inside which it
exists. If the physical interface is inside the logical interface, the setting of the physical interface returns to the default.
Regardless of the setting of this command, L2MS control frames might not be transmitted or received if any of the following
conditions exist.
The interface is in the Blocking status due to STP or the loop detection function
The switchport trunk native vlan none command has been specified
It is inside a logical interface
[Example]
Prevent port1.5 from transmitting or receiving L2MS control frames.
:
<1800-86400>
Acquisition interval (seconds)
:
L2MS control frames cannot be transmitted or received
:
L2MS control frames can be transmitted or received