Parameter
Flush chuck
DIR
S
α1
Z1
ZR
FR
Fixed
stop
Parameter
Function, withdrawing
Withdraw blank
Also take zero point
Work offset
- only when for "with-
draw NP" "yes"
Z1
F
Turning
Operating Manual, 01/2015, 6FC5398-8CP40-5BA2
Description
Flush counter-spindle chuck
Yes
•
No
•
Direction of rotation
Spindle rotates clockwise
•
Spindle rotates counter-clockwise
•
Spindle does not rotate
•
Spindle speed – (only when the spindle rotates)
Angular offset
Transfer position (abs.)
Position, feedrate reduction (abs or inc)
Position from which a reduced feedrate is used.
Reduced feedrate
Travel to fixed stop
Yes
•
The counter-spindle stops at a defined distance away from transfer position
Z1 and then traverses with a defined feedrate up to the fixed stop.
No
•
The counter-spindle traverses to the transfer position Z1.
Description
From main spindle
•
The blank is withdrawn from the main spindle
From counter-spindle
•
The blank is withdrawn from the counter-spindle
Also take zero point
Yes
•
No
•
Work offset in which the coordinate system offset by Z1 must be saved.
Basic reference
•
G54
•
G55
•
G56
•
G57
•
...
•
Amount by which the workpiece is withdrawn from the main spindle (inc)
Feedrate
Programming technology functions (cycles)
9.7 Additional cycles and functions in ShopTurn
Unit
rev/min
Degrees
mm/rev
Unit
mm/min
607