Skip levels, activate
Select the corresponding checkbox to activate the desired skip level.
Note
The "Program Control - Skip Blocks" window is only available when more than one skip level
is set up.
Procedure
Turning
Operating Manual, 01/2015, 6FC5398-8CP40-5BA2
1.
Select the "Machine" operating area.
2.
Press the <AUTO> or <MDA> key.
3
Press the "Prog. ctrl." and "Skip blocks" softkeys.
The "Program Control" window appears and shows a list of skip levels.
Machining the workpiece
5.9 Overstore
141