DCS
Allows customising of the tone cadence provided from the analogue trunk on a system-wide ba-
sis. There are three types of tone available through this MMC. The control of the tone cadence
may be changed from interrupt tone to continuous tone. Some DCS systems may require default
settings to comply with local operating companies. These tones are mainly used for performing
Automatic Redial depending on call progress tones on request from internal users on a trunk
call.
Once busy tone is detected from the Central Office, the call is automatically released and is
queued for redial after expiration of the Auto Redial Interval timer (see MMC 501).
FEATURE KEYS
DIAL 0
INTERRUPT TONE
DIAL 1
CONTINUOUS TONE
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPEAKER
TONES
BUSY TONE
RINGBACK TONE
DIAL TONE
ACTION
1.
Open programming and select 509
Display shows
2.
Press UP or DOWN key to select tone
Press LEFT soft key and advance to step 3
3.
Dial 0 for INTERRUPT tone or 1 for CONTINUOUS
tone
OR
Press UP or DOWN key to select and press RIGHT soft
key
4.
If you selected INTERRUPT tone, dial in new value(s)
for interrupt times (must be four digits each – sequence
on/off/on/off)
Press RIGHT soft key to advance cursor
Press LEFT soft key to retreat cursor
If valid entry, system returns to step 2
C.O. TONE CADENCE
3 3
7 7
CI
CII
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
MMC 509 [Compact I] (Page 1 of 2)
7 7
7 7
816
408i
DISPLAY
CO BUSY TONE
INTERRUPT TONE
CO RGBACK TONE
CONTINUOUS TONE
CO RGBACK TONE
INTERRUPT TONE
CO RGBACK T : 0400
0200 0400 0200
MMC PROGRAMS
NOVEMBER 2001
7 7