Mitsubishi Electric MELSEC-A0J2H Series Handbook page 64

Table of Contents

Advertisement

3
I/O MODULES REPLACEMENT
Specifications
Mechanical life
Electrical life
OFFON
Response
time
ONOFF
External
Voltage
supply
power
(Relay coil
Current
driving
power)
Specifications
Common terminal
arrangement
Operation indication
Current consumption
External connection
method
Applicable wire size
Applicable solderless
terminal
External dimensions
Weight
3
- 23
A0J2-E28DR output
specifications
20 million times or more
Rated switching voltage/current
load
200,000 times or more
(COS=0.7) 100,000 times or
(COS=0.7) 300,000 times or
200VAC 1.5A, 240VAC 1A
(COS=0.7) 200,000 times or
more
(COS=0.35) 100,000 times or
200VAC 0.75A, 240VAC 0.5A
(COS=0.35) 200,000 times or
200VAC 0.3A, 240VAC 0.15A
more
(COS=0.35) 300,000 times or
24VDC 1A, 100VDC 0.1A
(L/R=7ms) 200,000 times or
more
24VDC 0.3A, 100VDC 0.03A
10ms or less
12ms or less
24VDC±10%
Ripple voltage 4Vp-p or less
125mA
(24VDC TYP. All points are ON.)
A0J2-E28DR
8 points/common
(Common terminal: TB26)
3 points/common
(Common terminal: TB31)
Independent contact
(Common terminal: TB33)
Available (Turning ON the output
turns LED ON.)
0.130A (TYP.
All points are ON.)
36-point terminal block
connector
(M3 × 6 screws)
2
0.75 to 2mm
(Outside diameter: 8mm or less)
1.25-3, 1.25-YS3A,
2-S3, 2-YS3A,
(Sleeved solderless terminals
V1.25-3, V1.25-YS3A,
V2-S3, V2-YS3A
250(H) × 132(W) × 41(D) mm
98(H) × 27.4(W) × 90(D)mm × 2
0.68kg
: Compatible,
QY10
Compatibility
20 million times or more
Rated switching
voltage/current load
100,000 times or more
200VAC 1.5A, 240VAC 1A
more
200VAC 0.4A, 240VAC 0.3A
more
200VAC 1A, 240VAC 0.5A
more
more
24VDC 1A, 100VDC 0.1A
(L/R=7ms) 100,000 times or
more
(L/R=7ms) 300,000 times or
more
10ms or less
12ms or less
QX40/QY10
Compatibility
16 points/common
(Common terminal: TB17)
ON indication (LED)
0.05 +0.43 = 0.48A
(TYP. All points are ON.)
18-point terminal block
(M3 × 6 screws) 2 pieces
2
0.3 to 0.75mm
core
R1.25-3
cannot be used.)
0.16 + 0.22 = 0.38kg
: Partially changed, × : Incompatible
Precautions for replacement
Reduce the exchange intervals of
the modules as Mechanical/
Electrical Life is cut to about half.
External supply power is not
required.
Precautions for replacement
As the common changes from
three commons to a common,
wiring with a different voltage for
each common is not possible.
Review current capacity since
current consumption is increased.
×
×
Wiring change is required.
×
×
The dimensions are different.