Mitsubishi Electric MELSEC-A0J2H Series Handbook page 230

Table of Contents

Advertisement

Specifications
5VDC internal current
consumption
External
Voltage
supply
power
(Module
power
Current
supply)
External connection
36-point terminal block connector
method
Applicable wire size
(Applicable tightening torque 69N•cm)
Applicable solderless
terminal
Weight
External dimensions
*1
The value when using the input module, QX41Y41P, QX41, etc. and 5ms is set at input response time in I/O assignment
setting of PLC parameter (10ms is set at default).
*2
The value when using the output module, QX41Y41P, QY41P, etc.
*3
The weight of fixed stand of programmable controller depends on replacement type of renewal tool for A0J2.
*4
The external dimensions of the SC-A0JQIF56DR do not include those of its projection.
App
- 35
A0J2-E56DR
230mA (TYP. All points are ON.)
None
None
(M3 × 6 screws) 2 pieces
2
0.75 to 2mm
1.25-3, 1.25-YS3A, 2-S3,
2-YS3A, V1.25-3, V1.25-YS3A,
V2-S3, V2-YS3A
1.08kg
250(H) × 190(W) × 41(D)mm
SC-A0JQIF56DR
24VDC±10%
Ripple voltage 4Vp-p or less
200mA
36-point terminal block connector
(M3 × 6 screws) 2 pieces
2
0.75 to 2mm
(Applicable tightening torque 69N•cm)
1.25-3, 1.25-YS3A, 2-S3,
2-YS3A, V1.25-3, V1.25-YS3A,
V2-S3, V2-YS3A
0.62kg
*4
182(H) × 190(W) × 41(D)mm
: Compatible,
: Partially changed, × : Incompatible
Compatibility
Precautions for replacement
To deliver a power for programmable
controller operation, connecting a
×
module power supply to the interface
module, TB35 or TB36 is required.
If the voltage exceeds existing power
×
capacity, add 24VDC power supply
separately.
Also consider the weight of fixed stand
of programmable controller.
Check the dimensions since they
×
depend on the installation type
(building-up/horizontal/separate type).
*3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec q series

Table of Contents