REPLACING THE SPECIAL FUNCTION MODULE
(c) Programmable controller CPU I/O signal comparison
Input signal is different, so the sequence program must be changed.
Refer to the High-Speed Counter Module User's Manual for details regarding the I/O signals and
sequence program.
A0J2-D61S1
Device
Signal name
No.
X0
CH1 Counter value large
CH1 Counter value
X1
coincidence
X2
CH1 Counter value small
CH1 External preset request
X3
detection
X4
CH2 Counter value large
CH2 Counter value
X5
coincidence
X6
CH2 Counter value small
CH2 External preset request
X7
detection
X8
X9
XA
XB
XC
XD
XE
XF
X10
X11
Use prohibited
X12
X13
X14
X15
X16
X17
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
Device
Signal name
No.
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Use prohibited
Y8
Y9
YA
YB
YC
YD
YE
YF
Y10
CH1 Coincidence signal reset
Y11
CH1 Preset command
CH1 Coincidence signal
Y12
output enable
Y13
CH1 Down count command
Y14
CH1 Count enable
CH1 Present value read
Y15
request
CH1 External preset request
Y16
detection
Y17
CH2 Coincidence signal reset
Y18
CH2 Preset command
CH2 Coincidence signal
Y19
output enable
Y1A
CH2 Down count command
Y1B
CH2 count enable
CH2 Present value read
Y1C
request
CH2 external preset detection
Y1D
reset command
Y1E
Use prohibited
Y1F
QD62/QD62-H02
Device
Signal name
No.
X0
Module READY
CH1 Counter value large
X1
(Point No. 1)
CH1 Counter value
X2
coincidence (Point No. 1)
CH1 Counter value small
X3
(Point No. 1)
CH1 External preset request
X4
detection
CH1 Counter value large
X5
(Point No. 2)
CH1 Counter value
X6
coincidence (Point No. 2)
CH1 Counter value small
X7
(Point No. 2)
CH2 Counter value large
X8
(Point No. 1)
CH2 Counter value
X9
coincidence (Point No. 1)
CH2 Counter value small
XA
(Point No. 1)
CH2 External preset request
XB
detection
CH2 Counter value large
XC
(Point No. 2)
CH2 Counter value
XD
coincidence
(Point No. 2)
CH2 Counter value small
XE
(Point No. 2)
XF
Fuse blown detection flag
Device
Signal name
No.
CH1 Coincidence signal No. 1
Y0
reset command
Y1
CH1 Preset command
CH1 Coincidence signal
Y2
enable command
Y3
CH1 Down count command
CH1 Counter enable
Y4
command
CH1 External preset request
Y5
detection
CH1 Counter function
Y6
selection start command
Y7
CH1Coincidence signal No. 2
Y8
CH2 Coincidence signal No. 1
Y9
CH2 Preset command
CH2 Coincidence signal
YA
enable command
YB
CH2 Down count command
YC
CH2 Count enable command
CH2 External preset request
YD
detection
CH2 Counter function
YE
selection start command
CH2 Coincidence signal No. 2
YF
reset command
10