C0202 Parameter Limit Error (->S-0-0022); C0203 Parameter Calculation Error (->S-0-0022) - Bosch Rexroth IndraDrive Troubleshooting Manual

Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

9-50
Command Diagnostic Messages
C0202 Parameter limit error (->S-0-0022)
Cause
Parameter values required in communication
phase 4 are outside their allowed range of values
(minimum or maximum value)
C0203 Parameter calculation error (->S-0-0022)
Cause
Parameter values required in communication
phase 3 cannot be processed
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
Supported by Supply Unit:
While the command S-0-0128, C0200 Communication phase 4
transition check is executed, the limit values (minimum/maximum value)
are checked for some parameters. An error was detected during the
execution of the command.
Remedy
Write allowed values to parameters (cf.
minimum/maximum value) (these parameters can be
taken from list S-0-0022, IDN list of invalid operating
data for communication phase 3).
For removing command errors see "Command Errors"
C0202 - Attributes
Display:
C0202
Mess. no.:
C0202 (hex)
Supported by Firmware Variant:
Supported by Supply Unit:
While the command S-0-0128, C0200 Communication phase 4
transition check is executed, the internal parameter formats are
checked in order to ensure the internal processing. An error was detected
during the execution of the command.
Remedy
Write allowed values to parameters (the respective
parameters can be taken from list S-0-0022, IDN list of
invalid operating data for communication phase 3).
For removing command errors see "Command Errors"
C0203 - Attributes
Display:
C0203
Mess. no.:
C0203 (hex)
Rexroth IndraDrive
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
HMV01
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
HMV01
DOK-INDRV*-GEN-**VRS**-WA01-EN-P