How To Set A Parameter Value - Bosch Rexroth EFC 3600 Easy Start Manual

Hide thumbs Also See for Rexroth EFC 3600:
Table of Contents

Advertisement

Easy Start Guide
Bosch Rexroth EFC 3600 Series Inverter

6. How to set a Parameter value

This guide has been produced by The Inverter Drive Supermarket Ltd.
All content, including but not limited to graphics, text and procedures copyright
Drive Supermarket and must not be reproduced or altered without prior written permission.
6.1 Find Parameter Groups.
This example demonstrates the steps required to set
parameter b1.05 which is Maximum Frequency.
Press the "Func" key repeatedly until the display shows
"-b0-" (shown in the illustration opposite).
6.2 Find a Parameter Group eg. b1
There are a total of 12 parameter groups when
"Advanced Parameters" are enabled:-
Some parameter groups may be hidden when "Advanced
Parameters" are not enabled. Press "Set" to select "-b1-".
6.3 Find a Parameter eg. b1.05
The display will show "b1.00" to indicate parameter 00
within group b1.
Use the up and down keys to navigate to parameter
b1.05. Press the "Set" key to modify the parameter value.
Note that in some cases, the value of a parameter can be
restricted by the value of another parameter.
6.4 Change a Parameter value.
Use the up and down keys to increase or decrease the
value. Press and hold the up or down key to change the
value more quickly.
Press the "Set" key to save changes. The display will
show the next available parameter.
Press "Func" twice to exit.
©