Samsung OfficeServ 7200 Technical Manual page 64

Hide thumbs Also See for OfficeServ 7200:
Table of Contents

Advertisement

OfficeServ 7200
TECHNICAL MANUAL
Pin No.
Function
6.2.2 Connecting T1/E1/PRI
TEPRI boards can be connected to a T1/E1 C.O. line through a RJ-45 port. As shown
below, connect a T1 C.O. line or an E1 type PRI C.O. line to the T1/E1/PRI port of the
OfficeServ 7200 system.
Using a standard, straight through eight conductor data cable or straight through eight
conductor line cord to connect the customer provided Channel Service Unit (CSU) to
the TEPRI card as shown in
NOTES:
1. It may be necessary to cut off the CSU end of the cable and attach a different
connector to match that of the CSU. If possible, this connection should be soldered
because good connections are critical.
2. It is recommended that the CSU be connected to the network interface with a cable
supplied by the CSU manufacturer. If this is not possible or practical, a custom
cable has to be made up. This cable should be made from 22 gauge two pair cable
with each pair individually shielded. It is recommended that the connections on this
cable be soldered wherever possible to ensure good connections. The shielding of
the cable should be connected to ground at the CSU end only to prevent a ground
loop.
ORDERING A T1
The following information may be useful when ordering T1 service from the telephone
company.
PARAMETER
Framing type
Coding type
The coding type must be set up in the system to match the T1 span and is contained in
MMC 808.
1
2
3
-
-
-
Figure 6.1 8TRK Board
Figure 6.2.
6.2
Home Page
PART 6 SEPTEMBER 2005
4
5
6
C.O.
C.O.
-
TIP
RING
OPTIONS IN OFFICESERV 7200
Super Frame (SF) or D4
Extended Super Frame (ESF)
AMI or B8ZS