System Power: displays the source voltage for PORT A and PORT B separately. If the jumpers are configured
for INT/SRC, the voltage displayed will be approximately .3V less than the power supply voltage.
Acceptable voltage range is +11 to 24V.
If the voltage is less that 11V, UNDERVOLTAGE will be displayed.
If the voltage is more than 24V, OVERVOLTAGE will be displayed.
Enable sleep mode: If Station Master is
connected to a microKEYER II it will follow the
MK II sleep status.
NOTE: Sleep control has no function if Station
Master is not used with an MKII.
Enable button beep: When checked, SM will
generate short beeps on each button press.
Enable alarm beep: When checked, SM will generate three short beeps in an alarm condition.
IMPORTANT: The settings on this tab are valid only when Station Master is connected to microHAM Router. In
order to function in stand alone mode, the settings must be saved to Station Master as power-up defaults
using "Device | Store as Power-Up Settings."