microHAM STATION MASTER Manual page 67

Table of Contents

Advertisement

PA, DB15F
Pin #
Label
1
BAND DATA A
2
BAND DATA B
3
BAND DATA C
4
BAND DATA D
5
CI-V
6
KEYIN
7
KEYOUT
8
+12 OUT
9
POWER SW
10
NC
11
GND
12
GND
13
GND
14
GND
15
GND
SHELL
GND
ROTOR, DB15F
Pin #
Label
1
+12 OUT
2
CW-NC
3
CW-COM
4
AUX-NO
5
CCW-NC
6
CCW-COM
7
REF
8
ANALOG GND
9
GND
10
CW-NO
11
AUX-NC
12
AUX-COM
13
CCW-NO
14
PULSE IN
15
ANALOG IN
SHELL
GND
IMPORTANT: The CW, CCW and AUX relays are rated at 24V AC/DC, 3A maximum. If your rotator will exceed
these values, use external 12V power relays. Power for these relays can be supplied from pin 1, +12V OUT.
microHAM © 2016 All rights reserved
Description
TTL level BCD band data output bit 0
TTL level BCD band data output bit 1
TTL level BCD band data output bit 2
TTL level BCD band data output bit 3
CI-V port
Keying Input, connect to the PA KEY Output
Keying Output, max.+45V/800mA
+12V output, max.200mA. Output depends on main SM power
+12V output, max.100mA. Output for remote PA ON/OFF control
Not connected
Connected to the system ground and case.
Connected to the system ground and case.
Connected to the system ground and case.
Connected to the system ground and case.
Connected to the system ground and case.
Connected to the system ground and case.
Description
+12V output, max.200mA. Output depends on main SM power.
Relay output for CW direction, normally closed
Relay output for CW direction, common
Relay output for AUX output, normally open
Relay output for CCW direction, normally closed
Relay output for CCW direction, common
+9V reference output, max. 20mA (450 ohm)
Analog return for ANALOG IN input
Connected to the system ground and case.
Relay output for CW direction, normally open
Relay output for AUX output, normally closed
Relay output for AUX output, common
Relay output for CCW direction, normally open
Discrete input, max.5V/5mA
Analog input, Rin = 10K ohm, max +/-12V
Connected to the system ground and case.
67