Mitsubishi Electric Melsec Q Series Programming Manual page 479

Motion controller (sv13/sv22)
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

12 ERROR CODE LISTS
Error
Details
code
code
Name
Direct specification 64
bit Multiple CPU area
16376
device for CPU No.3
(U3E2\G10000 to)
read error
Direct specification 16
bit Multiple CPU area
16377
device for CPU No.4
(U3E3\G10000 to)
read error
Direct specification 32
bit Multiple CPU area
16378
device for CPU No.4
(U3E3\G10000 to)
read error
Direct specification 64
bit Multiple CPU area
16379
device for CPU No.4
(U3E3\G10000 to)
read error
Signed 16-bit integer
value conversion
16380
(SHORT) execution
error
Unsigned 16-bit
integer value
16381
conversion
(USHORT) execution
error
Signed 32-bit integer
value conversion
16382
(LONG) execution
error
Unsigned 32-bit
integer value
16383
conversion (ULONG)
execution error
32-bit
64-bit floating-
point type data
16386
conversion (DFLT)
execution error
64-bit
32-bit floating-
point type data
16387
conversion (SFLT)
execution error
Tangent (TAN)
16398
execution error
Arcsine (ASIN)
16399
execution error
Arccosine (ACOS)
16400
execution error
Square root (SQRT)
16402
execution error
BCD
BIN
16403
conversion (BIN)
execution error
BIN
BCD
16404
conversion (BCD)
execution error
Natural logarithm (LN)
16405
execution error
Absolute value (ABS)
16407
execution error
Error factor
Description
Multiple CPU area device number is outside
the range that set by the parameter.
The (S) data is outside the signed 16-bit
integer value range.
The (S) data is outside the unsigned 16-bit
integer value range.
The (S) data is outside the signed 32-bit
integer value range.
The (S) data is outside the unsigned 32-bit
integer value range.
The (S) data is not a valid 32-bit floating-
point type.
The (S) data is not in a valid 64-bit floating-
point type.
Or the converted value exceeded the 32-bit
floating-point type range.
(S) is 90+(180*n).
(n is an integer)
(S) is outside the range of -1.0 to 1.0.
(S) is a negative number.
Any digit of (S) has a value other than 0 to
9.
The (S) value is outside the range where
BIN data can be converted into BCD data.
(S) is 0 or a negative number.
The value of (S) is outside the range of the
absolute value conversion.
12 - 12
Error Processing
Correct the program so that Multiple CPU
area device number is within the range set
in the parameter.
Correct the program so that the (S) data is
within the signed 16-bit integer value range.
Correct the program so that the (S) data is
within the unsigned 16-bit integer value
range.
The block processing
Correct the program so that the (S) data is
on executing is
within the signed 32-bit integer value range.
stopped and the next
block is executed.
Correct the program so that the (S) data is
within the signed 32-bit integer value range.
Correct the program so that the (S) data is
valid as a 32-bit floating-point type.
Correct the program so that the (S) data is
valid as a 64-bit floating-point type and the
converted value is within the range of 32-bit
floating-point type.
Correct the program so that (S) is not
90+(180*n). (n is an integer)
Correct the program so that (S) is within the
range of -1.0 to 1.0.
Correct the program so that (S) is a positive
number.
Correct the program so that each digit of (S)
is 0 to 9.
Correct the program so that the (S) value is
within the range.
Correct the program so that (S) is a positive
number.
Correct the program so that the (S) value is
within the range.
Corrective Action