5 OPERATION CONTROL PROGRAMS
[Errors]
[Program examples]
(1) An operation error will occur if:
• The (S1) data is outside the range of 1 to 32.
• The (S2) data is outside the range of 1 to 32767.
• The vision system which is used in the vision program specified with (S1) has
not been logged on.
• The vision system parameter setting (Refer to APPENDIX 3.2.) is different from
the setting on the vision system and the job.
• The job loading is not completed when the specified timeout time has elapsed.
(1) Program which loads the job of the vision program No.2
MVLOAD K2
5 - 130