COMMAND CODE TITLE:
E0
Y
No.
MEANING
6
Instant System
Changeover by man-
ual operation
[8300R4]
NOTE 9
NOTE 10
NOTE 11
NOTE 12
NOTE 13
NOTE 1:
For the Data "MMDDHHmm", enter the Month, Date, and Time (hour and minute) of the
time, as shown below.
MM : Month (01 (Jan.)-12 (Dec.))
DD : Date (01-31)
HH : Hour (00-23)
mm : Minute (00-59)
NOTE 2:
Set the same Unit No. and Slot No. assigned by the first data.
NOTE 3:
"00000000-FFFFFFFF" is displayed as the second data when this command is executed.
You can confirm the port status of the blade which is accommodated to the specified slot by
this data display.
00000000: All ports are not in use
Other than 00000000: Ports in use are included.
NOTE 4:
For the blade reset while the system is operating, be sure to check the port status. The blade
reset must be executed when all ports are not in use.
NOTE 5:
Set the CME0 Y=5>00 when setting the new IPT (P2P CCIS) after the IPT (P2P CCIS)
installation (this data cannot be used once the reset has been executed by this data).
NOTE 6:
This data setting has no effect on services other than related to IPT (P2P CCIS) even if the
reset (CME0 Y=5>00) is executed after the IPT (P2P CCIS) installation.
NOTE 7:
Set the CME0 Y=5>01 when changing the commands (CM10 Y=2, CMA7 Y=44, 46, and
50) which require a reset related to IPT (P2P CCIS).
RESET/INSTANT SYSTEM CHANGEOVER
TYPE OF RESET
No.
MEANING
01
Fixed value
SETTING DATA
DATA
MM
Current time dis-
DD
played on Multiline
HH
Terminal/DESKCON
mm
To request the reset
immediately.
3-647
RELATED
COMMAND
MEANING
CMEC Y=5
NOTE 1
Continued on next page
NWA-033623-001 Rev.8.1
JANUARY/14/2011
CME0
91ch3008.fm

Advertisement

Table of Contents
loading