COMMAND CODE TITLE:
0C
Y
No.
MEANING
52
Remote System
Upgrade
UPDATING OF IP STATION FIRMWARE/REMOTE SYSTEM
UPGRADE
1ST DATA
DATA
MEANING
XX01
Changeover
(changeback)
time
XX: Unit No.
(01-50)
NOTE 1:
For CPU program changeover, the system is reset automatically. Therefore,
when executing the program download to multiple units, set the time for the sys-
tem to execute the program changeover for the Main Unit (Unit01) after the pro-
gram download to all units is completed.
NOTE 2:
If a specified changeover time is passed while CPU program is being download-
ed, the changeover of CPU program is executed immediately (second data be-
comes 000000000000).
NOTE 3:
If you set the second data to 000000000000 while CPU program is being down-
loaded, the CPU program changeover is executed after CPU program download
is completed.
NOTE 4:
This data is cleared after CPU program changeover is completed.
NOTE 5:
If the system is reset five times during about three minutes, the CPU program
changeback is executed automatically.
NOTE 6:
When the communication between Main Unit-Remote Unit/Primary Unit-
Secondary Unit cannot operate normally, "HARDWARE ERROR" is displayed.
DATA
YYYY MM
DD HH mm
000000000000
CCC
NONE
3-134
2ND DATA
MEANING
YYYY: Year (2011-2099)
MM
: Month (01-12)
DD
: Date (01-31)
HH
: Hour (00-23)
mm
: Minutes (00-59)
Executed immediately
Clear
No data
Continued on next page
NWA-033623-001 Rev.8.1
JANUARY/31/2012
CM0C
: Default
91ch3001.fm