COMMAND CODE TITLE:
0C
Y
No.
MEANING
53
System Upgrade
(Stand by CPU)
[8300R4]
UPDATING OF IP STATION FIRMWARE/REMOTE SYSTEM
UPGRADE
1ST DATA
DATA
MEANING
0101
Changeover
(changeback)
time
NOTE 1:
If a specified changeover time is passed while CPU program is being download-
ed, the changeover of CPU program is executed immediately (second data be-
comes 000000000000).
NOTE 2:
If you set the second data to 000000000000 while CPU program is being down-
loaded, the CPU program changeover is executed after CPU program download
is completed.
NOTE 3:
This data is cleared after CPU program changeover is completed.
NOTE 4:
If the system is reset five times during about three minutes, the CPU program
changeback is executed automatically.
NOTE 5:
When the communication between Active CPU and Stand by CPU cannot oper-
ate normally, "HARDWARE ERROR" is displayed.
DATA
YYYY MM
DD HH mm
000000000000
CCC
NONE
3-137
2ND DATA
MEANING
YYYY: Year (2011-2099)
MM
: Month (01-12)
DD
: Date (01-31)
HH
: Hour (00-23)
mm
: Minutes (00-59)
Executed immediately
Clear
No data
Continued on next page
NWA-033623-001 Rev.8.1
JANUARY/31/2012
CM0C
: Default