COMMAND CODE TITLE:
41
1ST
Y
MEANING
DATA
0
03
Timing for Pseudo-
Answer signal sent to
SMDR
04
Guard Timing of trunk
release
05
Recall Timing for
Non-exclusive Hold/
Call Park
06
Recall Timing for
Exclusive Hold/
Remote Hold
07
Recall Timing after
station release for call
transfer
09
Periodic Time Indica-
tion Tone
SYSTEM TIMER DATA
DEFAULT
NONE
00 01 02 03 04 05 06 07 08
20
4
24
8
seconds
NONE
01 02 03 04 05 06 ....................... 13
1.92
0 0.48 0.96 1.44 1.92 2.40 .................... 5.76 6.24
2.40
0.48 0.96 1.44 1.92 2.40 2.88 .................... 6.24 6.72
seconds
NONE
01 02 03 ............................................... 98
60
0
64
4
seconds
NOTE:
NONE
01 02 03 04 05 06 ....................... 98
236
0
240
4
NOTE:
seconds
NONE
01 02 03 04 05 06 ....................... 29
24
0
28
4
seconds
NONE
01 02 03 04 05 06 ....................... 16
192
32 64 96 128 160 192 ..................... 512 544
196
36 68 100 132 164 196 ..................... 516 548
seconds
2ND DATA
TIMER
8
12 16 20 24 28 32 36
12 16 20 24 28 32 36 40
4
8 ............................................... 388
8
12 .............................................. 392
When timer data 99 is assigned, the call is not
recalled.
4
8
12 16 20 ...................... 388
8
12 16 20 24 ...................... 392
When timer data 99 is assigned, the call is not
recalled.
4
8
12 16 20 ...................... 112 116
8
12 16 20 24 ...................... 116 120
3-335
CM41
INCREMENT
UNIT
4 seconds
14
0.48 seconds
99
4 seconds
99
4 seconds
30
4 seconds
17
32 seconds
Continued on next page