(2) Ethernet connection type: EtherNet/IP (AB)
This section describes [Connected Ethernet Controller Setting] when [AB Control/CompactLogix] is selected for the
model.
Item
Host
Net No.
*1
Station
Unit Type
IP address
Port No.
Communication format
Slot No.
*1
Set different values for [GOT Station] of [Detail Setting] and [Station] of [Connected Ethernet Controller Setting].
➠
■2. Communication detail settings
Description
The host is displayed.(The host is indicated with an asterisk (*).)
Set the network No. of the connected Ethernet module.
(Default: blank)
Set the station No. of the connected Ethernet module.
(Default: blank)
AB(EtherNet/IP) (fixed)
Set the IP address of the connected Ethernet module.
(Default: blank)
44818 (fixed)
TCP (fixed)
Set the slot No. connected to the CPU module in the PLC module.
(Default: blank)
Set value
1 to 239
1 to 64
AB(EtherNet/IP) (fixed)
PLC side IP address
44818 (fixed)
TCP (fixed)
0 to 16
10.3 Ethernet Connection
―
10
10 - 27