6.2.9
PLC Side Settings
■1. Communication and port settings
Make the communication and port settings with a peripheral tool.
Device name
*1
Address
Protocol
Mode
*2*3
Transmission speed
Data bit
Stop bit
Parity bit
Error check
*1
Set the address according to the Host Address setting on the GOT side.
For the Host Address setting on the GOT side, refer to the following.
➠
*2
Only transmission speeds available on the GOT side are shown.
Also, the setting range differs depending on the YASKAWA PLC model.
*3
The transmission speed setting must be consistent with that of the GOT side.
For the transmission speed setting on the GOT side, refer to the following.
➠
POINT
POINT
POINT
YASKAWA PLC
For details of YASKAWA PLCs, refer to the following manuals.
➠
YASKAWA PLC user's Manual
6.2.8 ■2. Communication detail settings
6.2.8 ■2. Communication detail settings
Set value
1 to 31
MEMOBUS
RTU
4800bps, 9600bps, 19200bps, 38400bps, 57600bps
8bits
1bit
Even
CRC16