Actual Signals; Start/Stop/Dir - ABB ACS800 Series Firmware Manual

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

No.
Name/Value
06.04 DATASET 3 WORD 1
06.05 DATASET 3 WORD 2
06.06 DATASET 3 WORD 3
06.07 DATASET 5 WORD 1
06.08 DATASET 5 WORD 2
06.09 DATASET 5 WORD 3

09 ACTUAL SIGNALS

09.01 AI1 SCALED
09.02 AI2 SCALED
09.03 AI3 SCALED
09.04 AI5 SCALED
09.05 AI6 SCALED
09.06 LCU ACT SIGNAL 1
09.07 LCU ACT SIGNAL 2

10 START/STOP/DIR

10.01 EXT1 STRT/STOP
NOT SEL
DI1
DI1P,2P
DI7
FIELDBUS
MASTER DRV
FBA & DI1
MSTR & DI1
FBA & MSTR
PARAM 10.05
10.02 EXT1 DIRECTION
FORWARD
DI2
DI3
DI4
Description
A 16-bit data word. Dancer / Tension setpoint (see
LOAD SETPT and
63.10
TENSION SETPOINT).
A 16-bit data word. Taper reference (see
and
63.12
TAPER REF SELECT).
A 16-bit data word. Speed match trim a mount (see
REF SEL).
A 16-bit data word. Percent Draw Trim for progressive. Draw from
overriding controller.
A 16-bit data word. See
90.08
A 16-bit data word. See
90.09
Signals for the Adaptive Program
Value of analog input AI1 scaled to an integer value.
Value of analog input AI2 scaled to an integer value.
Value of analog input AI3 scaled to an integer value.
Value of analog input AI5 scaled to an integer value.
Value of analog input AI6 scaled to an integer value.
A 16-bit data word. Line-side converter signal selected by
PAR1 SEL.
A 16-bit data word. Line-side converter signal selected by
PAR2 SEL.
The sources for external start, stop and direction control
Defines the connections and the source of the start and stop
commands for external control location 1.
This function is not selected.
Start and stop through digital input DI1. 0 = stop; 1 = start.
WARNING! After a fault reset, the drive will start if DI1 = 1.
Pulse start through DI1. Transition from 0 to 1 = start.
Pulse stop through DI2. Transition from 1 to 0 = stop.
See selection DI1.
See selection DI1. Instead of a digital input, the command comes from
06.01
DATASET 1 WORD 1 bit 03. See chapter
Starts and stops with the master drive.
Starts if DI1 and FIELDBUS = 1. Stops if DI1 or FIELDBUS = 0.
Starts if DI1 = 1 and MASTER DRV starts. Stops if DI1 = 0 or MASTER
DRV stops.
Starts if FIELDBUS = 1 and MASTER DRV starts. Stops if FIELDBUS
= 0 or MASTER DRV stops.
Source selected by
10.05
EXT 1 STRT PTR.
Enables the control of direction of rotation of the motor, or fixes the
directIon. See
60.05
WINDING MODE to ensure this is the parameter
to change.
Fixed to forward.
If digital input DI2 = 1, the direction is reverse.
See selection DI2.
See selection DI2.
62.10
62.12
TAPER REF SELECT
61.01
DATA 5 WORD 2.
DATA 5 WORD 3.
Fieldbus
Actual signals and parameters
67
FbEq
DANCER
1 = 1
1 = 1
SPD MTCH
1 = 1
1 = 1
1 = 1
1 = 1
2000 = 1 V
1000 = 1 mA
1000 = 1 mA
1000 = 1 mA
1000 = 1 mA
95.08
LCU
1 = 1
95.09
LCU
1 = 1
1
2
3
4
5
control.
6
7
8
9
10
1
2
3
4