Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

No.
Name/Value
DI4
DI5
DI6
DI7
DI8
DI9
DI10
DI11
DI12
FIELDBUS
65.14 CALC DIA USING
INTERNAL
PARAM 65.21
65.15 SENSOR MIN DIA
0.0...99999.0 mm
0.0...99999.0 inch
65.16 DIA > LIM1
1.0...99999.0 mm
1.0...99999.0 inch
65.17 DIA > LIM2
1.0...99999.0 mm
1.0...99999.0 inch
65.18 DIA < LIM1
1.0...99999.0 mm
1.0...99999.0 inch
65.19 DIA < LIM2
1.0...99999.0 mm
1.0...99999.0 inch
65.20 RESET WHILE RUN
NO
YES
65.21 EXT DIA SEL
AI1
AI2
AI3
AI5
Description
See selection DI2.
See selection DI2.
See selection DI2.
See selection DI2.
See selection DI2.
See selection DI2.
See selection DI2.
See selection DI2.
See selection DI2.
See selection DI2. Instead of a digital input, the command comes from
06.03
DATASET 1 WORD 3 bit 10. See chapter
Selects whether the internal diameter calculator is used or if an
external sensor is used.
Internal calculator.
External sensor using input selected by
Allows the minimum measured value of the sensor to represent
something other than 0 mm.
Setting range.
When the calculated diameter value is greater than this limit,
PACK STATUS BITS bit 11 is active. See chapter
Setting range.
When the calculated diameter value is greater than this limit,
PACK STATUS BITS bit 12 is active. See chapter
Setting range.
When the calculated diameter value is less than this limit,
PACK STATUS BITS bit 13 is active. See chapter
Setting range.
When the calculated diameter value is less than this limit,
PACK STATUS BITS bit 14 is active. See chapter
Setting range.
Allows the calculated diameter value to be reset while the machine is
running.
Not allowed.
Allowed.
Selects which input a diameter sensor is connected to. Used for
diameter reset and/or calculation.
Uses a sensor on analog input AI1 (voltage).
Uses a sensor on analog input AI2 (current).
Uses a sensor on analog input AI3 (current).
Uses a sensor on analog input AI5 (voltage or current).
Fieldbus
control.
65.21
EXT DIA SEL.
03.15
Fieldbus
control.
03.15
Fieldbus
control.
03.15
Fieldbus
control.
03.15
Fieldbus
control.
Actual signals and parameters
121
FbEq
4
5
6
7
8
9
10
11
12
13
0
65535
10 = 1 mm
10 = 1 inch
10 = 1 mm
10 = 1 inch
10 = 1 mm
10 = 1 inch
10 = 1 mm
10 = 1 inch
10 = 1 mm
10 = 1 inch
0
65535
1
2
3
4