Fieldbus Data; Standard Modbus; Applic Controls - ABB ACS800 Series Firmware Manual

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

100
No.
Name/Value
50.08 ENC CABLE CHECK
NO
WARNING
FAULT

51 FIELDBUS DATA

52 STANDARD MODBUS

52.01 STATION NUMBER
1...247
52.02 BAUDRATE
600
1200
2400
4800
9600
19200
52.03 PARITY
NONE1STOPBIT
NONE2STOPBIT
ODD
EVEN

60 APPLIC CONTROLS

60.01 INERTIA COMP ENBL
NO
YES
60.02 GEAR RATIO
0.10...1000.00 (:1)
60.03 WEB LOSS TRIP
0.0...100.0%
Actual signals and parameters
Description
Selects the drive operation when encoder signal is missing.
Note: Monitoring is only for RTAC-03. For more information, see
RTAC-03 Pulse Encoder Interface Module User's Manual
[3AFE68650500 (English)].
No action.
Drive generates warning ENC CABLE.
Drive trips on fault ENC CABLE.
The parameters are visible and need to be adjusted only when a
fieldbus adapter module (optional) is installed and activated by
FIELDBUS MODULE. For details on the parameters, refer to the
manual of the fieldbus module.
These parameter settings will remain the same even if the macro is
changed.
The setting for the standard modbus link.This group will be Visible only
when Standard Modbus is selected by
and ensure that RMBA module is inserted in Option Slot1.
Defines the address of the device. Two units with the same address
are not allowed on-line.
Address
Defines the transfer rate of the link.
600 bit/s.
1200 bit/s.
2400 bit/s.
4800 bit/s.
9600 bit/s.
19200 bits/s.
Defines the use of parity and stop bit(s). The same setting must be
used in all on-line stations.
No parity bit, one stop bit.
No parity bit, two stop bits.
Odd parity indication bit, one stopbit.
Even parity indication bit, one stopbit.
Non-macro specific winder parameters.
Allows inertia compensation to be used and makes Group 64 visible.
Inertia compensation is not needed.
Inertia compensation is needed.
Ratio between motor rpm and spindle rpm.
Setting range.
The percent (of maximum tension) deviation allowed before error
detection.
Setting range.
98.02
98.02
FIELDBUS MODULE
FbEq
0
1
2
1 = 1
1
2
3
4
5
6
1
2
3
4
0
65535
100 = 1
10 = 1%