ABB ACS800 Series Firmware Manual page 89

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

No.
Name/Value
FIELDBUS
MASTER DRV
16.05 USER MACRO IO CHG
NOT SEL
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
DI9
DI10
DI11
DI12
FIELDBUS
16.06 LOCAL LOCK
OFF
ON
16.07 PARAMETER SAVE
DONE
SAVE...
16.09 CTRL BOARD SUPPLY
INTERNAL 24 V
EXTERNAL 24 V
Description
See selection DI2. Instead of a digital input, the selection comes from
06.01
DATASET 1 WORD 1 bit 07 See chapter
The reset signal comes from the master drive. The master drive must
be stopped (not in RUN).
Enables the change of the User Macro through a digital input. See
99.02
APPLICATION MACRO. The change is only allowed when the
drive is stopped. During the change, the drive will not start.
Note: Always save the User Macro by
after changing any parameter settings, or reperforming the motor
identification.The last settings saved by the user are loaded into use
whenever the power is switched off and on again or the macro is
changed. Any unsaved changes will be lost.
Note: The value of this parameter is not included in the User Macro. A
setting once made remains despite the User Macro change.
User macro change is not possible through a digital input.
Falling edge of digital input DI1: User Macro 1 is loaded into use.
Rising edge of digital input DI1: User Macro 2 is loaded into use.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1. Instead of a digital input, the selection comes from
06.01
DATASET 1 WORD 1 bit 01. See chapter
Disables entering to local control mode (LOC/REM key of the panel).
WARNING! Before activating, ensure that the control panel is
not needed for stopping the drive!
Local control allowed.
Local control disabled.
Saves the valid parameter values to the permanent memory.
Note: A new parameter value of a standard macro is saved
automatically when changed from the panel but not when altered
through a fieldbus connection.
Saving started.
Saving is done.
Defines the source of the control board power supply.
Note: If an external supply is used but this parameter has value
INTERNAL 24 V, the drive trips to a fault at power switch off.
Internal
External. The control board is powered from an external supply.
Fieldbus
control.
99.02
APPLICATION MACRO,
Fieldbus
control.
Actual signals and parameters
77
FbEq
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
0
65535
0
1
1
2