ABB ACS800 Series Firmware Manual page 164

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

152
Table 6 Auxiliary Status Word 4 (Actual Signal 02.28)
Bit
0
1
2
3
4
5
6
7...15
Table 7 Auxiliary Status Word (Actual Signal 02.27).
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14...15
*See Master/Follower Application Guide (3AFY58962180 [English]).
Fieldbus control
Name
Description
SPEED 1 LIM
Output speed has exceeded or fallen below supervision limit 1. See
group
Reserved
Reserved
REF 1 LIM
Reference 1 has exceeded or fallen below the set supervision limit.
See group
Reserved
TORQUE 1 LIM
The motor torque has exceeded or fallen below the TORQUE1
supervision limit. See group
TORQUE 2 LIM
The motor torque has exceeded or fallen below the TORQUE2
supervision limit. See group
Reserved
Name
Reserved
OUT OF WINDOW
Reserved
MAGNETIZED
Reserved
SYNC RDY
1 START NOT DONE
IDENTIF RUN DONE
START INHIBITION
LIMITING
TORQ CONTROL
ZERO SPEED
INTERNAL SPEED FB
M/F COMM ERR
Reserved
32
SUPERVISION.
32
SUPERVISION.
32
SUPERVISION.
32
SUPERVISION.
Description
Speed difference is out of the window (in speed control)*.
Flux has been formed in the motor.
Position counter synchronized.
Drive has not been started after changing the motor
parameters in group 99.
Motor ID Run successfully completed.
Prevention of unexpected start-up active.
Control at a limit. See actual signal
Torque reference is followed*.
Absolute value of motor actual speed is below zero speed
limit (4% of synchronous speed).
Internal speed feedback followed.
Master/Follower link (on CH2) communication error*.
02.23
LIMIT WORD 1.