ABB ACS800 Series Firmware Manual page 131

Center winder/unwind control program
Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

No.
Name/Value
65.01 MIN CORE DIAMETER
1.00...9999.00 mm
1.00...9999.00 inch
65.02 MAX ROLL DIAMETER
1...99999 mm
1...99999 inch
65.03 DIAMETER RESET
DI3
DI3, DI4
DI5
DI5, DI6
DI9
DI9, DI10
FIELDBUS
DI3 – P65.21
FBA – P65.21
MASTER DRV
65.04 DIAMETER RESET 2
1.0...99999.0 mm
1.0...99999.0 inch
65.05 DIAMETER RESET 3
1.0...99999.0 mm
1.0...99999.0 inch
65.06 MIN DIA CALC SPD
1.0...1000.0 m/min
1.0...1000.0 fpm
Description
Set to the minimum core diameter that will be used on the machine.
Example: The machine uses three different cores to run varying
grades of material. The cores are 4" (100 mm), 6" (150 mm), and 8"
(200 mm). MIN CORE DIAMETER must be set to 4" (100 mm). When
the other cores are used, the proper diameter reset selection will set
the diameter to the correct core; see below.
Setting range.
Maximum roll diameter that will be used in the machine.
Setting range.
Sets or selects the activation signal source for resetting the calculated
diameter.
Digital input DI3 = 1 resets the diameter to
DIAMETER or
65.02
MAX ROLL DIAMETER (depends on if winding
or unwinding).
Digital input DI3 = 1 and DI4 = 0 resets the diameter as selection DI3.
Digital input DI3 = 0 and DI4 = 1 resets the diameter to
DIAMETER RESET 2.
Digital input DI3 = 1 and DI4 = 1 resets the diameter to
DIAMETER RESET 3.
See selection DI3.
See selection DI3, DI4.
See selection DI3.
See selection DI3, DI4.
See selection DI3, DI4. Instead of digital inputs, the command comes
from
06.03
DATASET 1 WORD 3 bits 06 and 07. See chapter
control.
Digital input DI3 = 1 resets the diameter to the value read by the
analog input selected in
65.21
06.03
DATASET 1 WORD 3 bit 06 = 1 resets the diameter to the value
read by the analog input selected in
Resets the diameter as selection DI3.
Optional value used for diameter reset.
Setting range.
Optional value used for diameter reset.
Setting range.
This is used to prevent incorrect diameter calculation at very low motor
speeds (Motor Actual Speed may not be extremely accurate at very
low speeds). This can be set to 0.1% lower than the minimum
operational web speed; which is the lowest speed at which the line
may be operated for more than 1 minute.
Setting range.
65.01
MIN CORE
65.04
65.05
EXT DIA SEL.
65.21
EXT DIA SEL.
Actual signals and parameters
119
FbEq
100 = 1 mm
100 = 1 inch
1 = 1 mm
1 = 1 inch
1
2
3
4
5
6
7
Fieldbus
8
9
10
10 = 1 mm
10 = 1 inch
10 = 1 mm
10 = 1 inch
10 = 1 m/min
10 = 1 fpm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-u2Acs800-u7Acs800-u4

Table of Contents