1.1

Processing of Each Function

The functions are processed in the order shown below. If multiple functions are enabled, the output of the first processed
function is used as the input of the next function.
Analog input
(1)
(CH1 to 8)
No.
Processing details
(1)
Input signal error detection function
(2)
The A/D conversion is executed in one of the following A/D conversion methods.
• Sampling processing
• Count average
• Time average
• Moving average
• Primary delay filter
(3)
Scaling function
(4)
Warning output function (rate alarm)
(5)
Warning output function (process alarm)
(6)
Maximum value/minimum value hold function
Digital output value
These values are the digital values after the sampling processing, each averaging processing, or primary delay filter has been
performed.
Digital operation value
These values are obtained by operating a digital output value using the scaling function. When the scaling function is not
used, the same value as the digital output value is stored.
Maximum and minimum values
The maximum and minimum values of the digital operation values are stored.
(2)
(4)
(5)
(3)
CH
Digital output value
CH
Maximum value
(6)
CH
Minimum value
CH
Digital operation value
1.1 Processing of Each Function
1
1 FUNCTIONS
15