The transverse cables inside the rack are bound at the inner part of the cross
rod, and the longitudinal cables inside the rack are bund along the cable
trough at both sides.
All the cables between racks are through the holes at the edge of the cabinet
and connected to the corresponding position.
The screws of the fan are fastened securely.
The fan can be switched on or off normally. Its rotation is normal and the
alarms can be reported normally.
The external antenna lightning arrester of the cabinet is correctly installed in
accordance with the design, and the connection should be reliable and in
order.
The cables made on site are firmly connected and in good contact. The
naked part is wrapped in insulating tape or protection tube. The connectors
of cables are firmly crimped.
The screws, fixing the cabinet or the base/support with the floor, are
secured.
The insulating materials, plain washers, spring washers, screws and bolts
are installed in order.
When leveling the base by adjusting bolts, use washers to enlarge the stress
surface area to avoid distortion of the base.
The upper surface of the antistatic floor in the equipment room is lower than
the lower surface of the base so as not to affect heat dissipation of the base.
The mechanical parts of the cabinet are correctly installed.
The environment alarm collection cables connected to BTS are equipped
with reliable lightning protection devices.
Cable labels are filled in and attached according to the specifications. The
labels are neatly arranged in the same direction.
They can be uniformly prepared as per the requirements of users for the
convenience of query. It is recommended to attach labels 2cm (0.8 in.) away
from the connector.
The cables are bundled neatly. The interval between cable ties are even.
The cables are properly fastened. The direction of the cable ties are the
same. All the cable ties are cut without sharp ends
PVC troughs are installed for the power cables and signal cables of the
alarm box on the wall. Redundant cables are coiled up and placed under the
floor of the alarm box or on the wiring ladder.
No part of the rack is distorted.
Dummy panels are installed for empty slots.
The boards can be inserted or removed smoothly.
The screws (if any) on the panel of the board are properly fastened, and the
spring wire is intact.
Huawei Technologies Proprietary
Chapter 6 Checking Cabinet Installation
Requirement
6-2