Installing Cables Of Combined Cabinets; Installing Rs485 Serial Port Cable - Huawei BTS3606 Installation Manual

Airbridge cdma base station
Hide thumbs Also See for BTS3606:
Table of Contents

Advertisement

Installation Manual – BTS3606 Cabinet Installation
Airbridge BTS3606&3606A CDMA Base Station
I. Setting EAC Extended Port
To set the EAC extended port, proceed as follows:
1)
Start the Service Maintenance System or run the Telnet.
2)
Enter the command SET CBTSEACEXTALM in the command input box.
3)
Press <Enter>.
4)
Enter the information including the BTS Name, BTS ID, and IO ID (extended port
number).
5)
Select the Operate Mode.
6)
Enter the alarm information if the Operate Mode is set to DEF.
7)
Press F9 to execute the command.
II. Querying EAC Extended Port
To query the setting of the EAC extended port, proceed as follows:
1)
Start the Airbridge BTS3606 Maintenance System or run the Telnet.
2)
Enter the command DSP CBTSEACEXTALM in the command input box.
3)
Press <Enter>.
4)
Enter the BTS Name and BTS ID.
5)
Press <F9> to execute the command.

4.8 Installing Cables of Combined Cabinets

When BTS3606 cabinets are combined, you need to install RS485 serial port cables,
optical fibers, and 10 MHz clock cables.
Note:
Before connecting cables of combined cabinets, check that the TMCM is inserted into
the slot of the BCKM at the upper half part of the combined subrack, and the LECM
into the slot of the CTRM.

4.8.1 Installing RS485 Serial Port Cable

To install an RS485 serial port cable, proceed as follows:
1)
Remove the rear door from the extension cabinet.
2)
Remove the serial port cable from the DB26 socket on the upper/lower RF
backplane.
3)
Connect one end of the RS485 serial port cable to the DB26 socket on the upper
RF backplane.
Huawei Technologies Proprietary
4-27
Chapter 4 Installing Cables

Advertisement