Output Data: Mvout - Mitsubishi Electric R16MTCPU Programming Manual

Hide thumbs Also See for R16MTCPU:
Table of Contents

Advertisement

Output data: MVOUT

Format
MVOUT (S1), (S2), (S3), (S4)
Setting data
■Usable data
: Usable
Setting
Usable Data
data
Bit
device
(S1)
(S2)
(S3)
(S4)
*1 Specify the start device which stores the character string data. The character string can be specified directly.
*2 Data is the same format as data to be transferred. The character string can be specified directly.
■Description, data type of result
Setting data
Description
(S1)
Vision system (camera) No. to transfer data (1 to 32)
(S2)
Spreadsheet cell or tag to transfer data
(S3)
Data to be transferred
(S4)
Timeout time until data is transferred to vision system (1 to 32767) [10ms]
Processing details
• Data specified with (S3) is transferred to spreadsheet cell or tag specified with (S2) of vision system specified with (S1).
• The Motion SFC program execution transits to the next block without waiting for the process completion. After process
completion, the status storage device value set in the Ethernet communication line setting parameter is 20 (reception
enabled).
• In (S2), write directly the spreadsheet cell or tag as a 32 one-byte character or less character string enclosed with double
quotation, or set the head of a device in which a 32 one-byte character or less character string is stored. Designation
methods of the character string are shown below.
Designation methods
Setting with cell
Setting with tag
• In (S3), set the head of a device that store data to be transferred to spreadsheet cell or tag. Also, the character string of
constants or 99 one-byte character or less character string can be specified directly.
[Indirect specification]
Data type specified with (S3)
16-bit integer value type
32-bit integer value type
64-bit floating-point type
4 OPERATION CONTROL PROGRAMS
252
4.17 Vision System Dedicated Function
Number of basic steps
15 or more
Word device
16-bit
32-bit
64-bit
integer
integer
floating
type
type (L)
point
type (F)
*1
*2
*2
*2
Description
The spreadsheet row (A to Z) and line (0 to 399) are arranged and written.
(Example) When cell is A5, "A5" is set.
The Symbolic tag name is written in the original state.
(Example) When tag is Job.Pass_count, "Job.Pass_count" is set.
Number of points
1 point
Consecutive 2 points
Consecutive 4 points
Usable steps
F/FS
Constant
16-bit
32-bit
64-bit
integer
integer
floating
type
type
point
(K/H)
(K/H, L)
type (K)
*2
*2
*2
G
Calculation
Bit
expression
conditional
expression
Data type of result
Setting example
D1000
D2000L
D3000F
Comparison
conditional
expression

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R64mtcpuMelsec iq-r seriesR32mtcpu

Table of Contents