Reset A Status Storage Device: Mvfin - Mitsubishi Electric R16MTCPU Programming Manual

Hide thumbs Also See for R16MTCPU:
Table of Contents

Advertisement

Reset a status storage device: MVFIN

Format
MVFIN(S)
Setting data
■Usable data
: Usable
Setting
Usable Data
data
Bit
device
(S)
■Description, data type of result
Setting data
Description
(S)
Vision system (camera) No. to reset the status storage device (1 to 32)
Processing details
• The status storage device value set in the Ethernet communication line setting parameter specified with (S) is 20 (reception
enabled).
• When a trigger is issued to the vision system, the status storage device is reset by MVFIN instruction in advance, and the
process completion for trigger needs to be detected.
Operation error
An operation error will occur if:
• The (S) data is outside the range of 1 to 32.
• The vision system specified with (S) has not been logged on.
• The vision system parameter setting is different from the setting on the vision system.
• The status storage device value set in the Ethernet communication line setting parameter is not 20 (reception enabled), 40
(Image data reception completed), or 50 (value cell reception completed).
Program example
■Program which resets the status storage device for the vision system (camera) 1
MVFIN K1
4 OPERATION CONTROL PROGRAMS
254
4.17 Vision System Dedicated Function
Number of basic steps
6
Word device
16-bit
32-bit
64-bit
integer
integer
floating
type
type (L)
point
type (F)
Usable steps
F/FS
Constant
16-bit
32-bit
64-bit
integer
integer
floating
type
type
point
(K/H)
(K/H, L)
type (K)
G
Calculation
Bit
expression
conditional
expression
Data type of result
Comparison
conditional
expression

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R64mtcpuMelsec iq-r seriesR32mtcpu

Table of Contents